1.1 Kind of query: |
|
Query without Dataspy- Connector:
On a spy-PC BinTerm need two serial COM-Ports. BinTerm send all data from
the one serial port to the other
port. Additional BinTerm can protocol
the handshake- signals from the two ports. |
|
1.1.1
Query with Dataspy Mini - I
or Mini - II: |
With them, you can query a
serial data stream in both directions. BinTerm need only one serial COM-
port.
|
|
|
1.1.2
Query with RS422 / RS485- Changer on RS232:
For spy from a RS422 / RS485- bus system. With the sending- function from
BinTerm can you send a telegram into the bus.
|
|
1.1.3
Query with LIN-Bus Changer on RS232:
For spy from a RS422 / RS485- bus system. With the sending- function from
BinTerm can you send a telegram into the bus. |
|
1.1.4
Query with TTL / RS232 Changer on :
A changer from RS232 into TTL signal. A very simple way to connect to a
microcontroller, who have no RS232 converter. |
|
1.1.5
Query with USB- Dataspy:
The USB- Dataspy is a multifunction device with them you can not only
spy a RS232- connection, you can spy RS422/485 too. The firmware is independent
from Windows- COM- port- functions, so BinTerm can detect all data and
direction lines correctly.
With the additional extension- board "CAN", you can protocoling
the CAN- Bus 2.0A and 2.0B with BinTerm.
|
|
Function overview:
|
without
hardware
|
|
|
|
|
|
|
|
BinTerm |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
Windows NT4.0 |
X
|
X
|
X
|
X
|
X
|
X
|
|
|
Windows 98,
ME, 2000, XP |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
can use with
other software |
|
|
|
X
|
X
|
X
|
|
|
V24 protocoling |
X
|
X
|
X
|
|
|
|
X
|
X
|
V24 protocoling
full duplex |
X
|
|
|
|
|
|
X
|
X
|
V24 protocoling
from handshake-lines |
X
|
|
|
|
|
|
X
|
X
|
V24 protocoling
from frame errors |
|
|
|
|
|
|
X
|
X
|
V24 can data
send |
X
|
|
X
|
|
|
|
X
|
X
|
V24 change from
RxD and TxD with jumper |
|
|
X
|
|
|
|
|
|
RS485 protocoling |
|
|
|
X
|
|
|
X
|
X
|
RS422 protocoling |
|
|
|
|
|
|
X
|
|
RS4xx protocoling
from frame errors |
|
|
|
|
|
|
X
|
X
|
RS4xx data send |
|
|
|
X
|
|
|
X
|
X
|
LIN- Bus Protokollierung |
|
|
|
|
X
|
|
|
X
|
LIN- Bus Daten
senden |
|
|
|
|
X
|
|
|
X
|
LIN- Bus Protokollierung |
|
|
|
|
X
|
|
|
X
|
CAN protocoling |
|
|
|
|
|
|
X
|
X
|
CAN data send |
|
|
|
|
|
|
X
|
X
|
measure baud
rate |
|
|
|
|
|
|
X
|
X
|
measure frequency |
|
|
|
|
|
|
X
|
X
|
connectors required
from PC |
2x
serial
|
1x
serial
|
1x
serial
|
1x
serial
|
1x
seriell
|
1x
seriell
|
1x
USB
|
1x
USB
|
external
power supply required |
|
no
|
no
|
no
|
no
/ +12V
|
no
/ +5V
|
no
|
no
|
|